Conductor Advisor by Epsilon Cable

Find the right HVCRC conductor for your line.

Enter your existing conductor, target ampacity and operating conditions. Get a ranked selection of relevant composite core conductor options, with ampacity calculated for your line.

Launch Conductor Advisor

5 to 10 min · Personalized recommendation

Turn complex line requirements and constraints into a focused technical recommendation, without searching through hundreds of conductors configurations

Select your current conductor from the database or enter its specifications manually. Conductor Advisor uses your line conditions and performance target to prioritize the most relevant HVCRC solutions.

Optimize for what your line needs most.

Conductor advisor adapts its recommendations to your priority.

Increase line ampacity

Identify HVCRC options capable of meeting your target ampacity while remaining aligned with the diameter, weight and mechanical constraints of the existing line.

Reduce electrical losses

Prioritize lower-resistance options while meeting your target ampacity and reference mechanical requirements.

Reduce mechanical stress

Explore options that can reduce structural loading by optimizing conductor diameter and linear weight.

Get your recommendations in three steps

Have your line information ready and the complete assessment usually takes less than ten minutes.

Describe your existing line

Select the conductor currently installed or enter its electrical and mechanical specifications.

ref

Hawk
…

unit system

metric (SI)
…

02

Define targets and conditions

Enter the ampacity you need, operating temperature and environmental conditions.

Target ampacity

900 A
…

Ambient temperature

30°C
…

Wind velocity

0.5 m/s
…

03

Compare and download

Review ranked HVCRC recommendations and download a personalized technical data sheet.

#1 HVCRC® 240-47

PDF

#2 HVCRC® Lite (AL0) 250-30

PDF

#3 HVCRC® Lite (AL1) 240-55

PDF

What to have ready

For the most relevant recommendation

  • Current conductor type and specifications
  • Maximum AL1 operating temperature
  • Current and target ampacity
  • Representative weather and site conditions

Results built around your requirements.

Every recommendation is based on the conductor properties and operating conditions you provide.

  • Ranked HVCRC recommendations
  • Ampacity calculated for your conditions
  • Clear electrical and mechanical comparison
  • Personalized PDF technical data sheet

Launch Conductor Advisor

Example of ranked HVCRC conductor recommendations with calculated ampacity and downloadable technical data sheets.

A recognized methodology.

Get recommendations using reference calculation methods.

ampacity methodology

Ampacity calculations apply the current–temperature methodology described in IEEE 738-2023 to the line conditions entered by the user.

Calculation engine

The calculation engine and recommendation logic were developed in-house by Epsilon Cable’s engineering team.

Before you begin.

Yes. Access is free.

Most users receive their recommendations in 5 to 10 minutes when the existing conductor data, target ampacity and line conditions are available.

You can manually enter its main electrical and mechanical specifications and continue the assessment.

No. The results provide a preliminary technical recommendation and must be validated through a comprehensive engineering study before final conductor selection.

Give Conductor Advisor a try